1. Home
  2. DeviceAID Home
  3. Library - Imaging

Manufacturer

Category

Transducer Frequency (MHz)

Maximum Diameter Penetration (mm)

Resolution: Axial (μm)

Crossing Profile (F)

Opticross

Category: Intravascular Ultrasound

Transducer Frequency (MHz): 60

Maximum Diameter Penetration (mm): 6

Resolution: Axial (μm): 38

Crossing Profile (F): 3.1

view details

Opticross 6

Category: Intravascular Ultrasound

Transducer Frequency (MHz): 60

Maximum Diameter Penetration (mm): 6

Resolution: Axial (μm): 38

Crossing Profile (F): 3.1

view details

Eagle Eye Platinum

Manufacturer: Philips

Category: Intravascular Ultrasound

Transducer Frequency (MHz): 20

Maximum Diameter Penetration (mm): 20

Resolution: Axial (μm): <170

Crossing Profile (F): 3.5

view details

Eagle Eye Platinum ST

Manufacturer: Philips

Category: Intravascular Ultrasound

Transducer Frequency (MHz): 20

Maximum Diameter Penetration (mm): 20

Resolution: Axial (μm): <170

Crossing Profile (F): 3.5

view details

Resolution

Manufacturer: Philips

Category: Intravascular Ultrasound

Transducer Frequency (MHz): 45

Maximum Diameter Penetration (mm): 14

Resolution: Axial (μm): 50

Crossing Profile (F): 3.2

view details

Refinity ST

Manufacturer: Philips

Category: Intravascular Ultrasound

Transducer Frequency (MHz): 45

Maximum Diameter Penetration (mm): 14

Resolution: Axial (μm): NA

Crossing Profile (F): 3

view details

Kodama

Manufacturer: ACIST by Bracco Company

Category: Intravascular Ultrasound

Transducer Frequency (MHz): 40/60

Maximum Diameter Penetration (mm): NA

Resolution: Axial (μm): NA

Crossing Profile (F): <3.4

view details

Dualpro IVUS+NIRS

Manufacturer: Infraredx, Nipro Company

Category: Intravascular Ultrasound

Transducer Frequency (MHz): 35-65

Maximum Diameter Penetration (mm): 16

Resolution: Axial (μm): NA

Crossing Profile (F): 3.2

view details

Novasight Hybrid

Manufacturer: CONAVI

Category: Intravascular Ultrasound, OCT

Transducer Frequency (MHz): 40 (IVUS), 1310 nm (OCT)

Maximum Diameter Penetration (mm): 16

Crossing Profile (F): 2.8

view details

Dragonfly

Manufacturer: Abbott

Category: Optis Intravascular Imaging Catheter

Maximum Diameter Penetration (mm): 2-3.5

Resolution: Axial (μm): 10-20

Crossing Profile (F): 2.7

view details
Case ExamplesEducational Content

ATHERECTOMY COMPLICATIONS

Case ExamplesEducational Content

BYPASS GRAFT COMPLICATIONS

ModelBurst (ATM)Diameter (mm)Balloon Length (mm)
681215202530
MINI TREK (CTO INDICATED)1.271.2✓✓✓✓✓
1.561.5✓✓✓✓✓
2.172✓✓✓✓✓✓*✓*
TREK2.372.25✓✓✓✓✓✓✓
2.672.5✓✓✓✓✓✓✓
2.912.75✓✓✓✓✓✓✓
3.113✓✓✓✓✓✓✓
3.53.25✓✓✓✓✓✓✓
3.73.5✓✓✓✓✓✓✓
3.943.75✓✓✓✓✓✓✓
4.324✓✓✓✓✓✓✓
4.864.5✓✓
5.365✓✓
*Only available as RX, not as OTW. Other sizes available in both versions.
Retrieved on April 07 2022 from Abbott product ordering information. Please look at the company's files for the latest available data on device configurations and avilability in your area.

Left Main DK Crush Video ID