1. Home
  2. DeviceAID Home
  3. Library - Vascular Closure

Manufacturer

Type

Category (Extravascular/Intravascular, Manual Compression)

Filter - Implant Material

Filter - Suitable Arteriotomy Size (F)

Resorption of Implant (days)

Filter - Preferred Use

Perclose Proglide

Manufacturer: Abbott

Type: Vascular closure device (VCD)

Category (Extravascular/Intravascular, Manual Compression): Intra and Extravascular

Implant Material: Polypropylene monofilament Suture

Suitable Arteriotomy Size (F): 5-21 (Artery), 5-21 (Vein)

Resorption of Implant (days): NA

Preferred Use: Common Femoral artery (5-21F), Vein (5-24 F). Two devices with the pre-close technique are required for puncture size >8F. No re-access restrictions.

view details

Prostar XL

Manufacturer: Abbott

Type: Vascular closure device (VCD)

Category (Extravascular/Intravascular, Manual Compression): Intravascular VCD

Implant Material: Two braided polyester sutures

Suitable Arteriotomy Size (F): 8.5-10

Resorption of Implant (days): NA

Preferred Use: Common Femoral artery (8.5-10F), Vein (5-24 F). No re-access restrictions.

view details

Manta

Manufacturer: Teleflex

Type: Vascular closure device (VCD)

Category (Extravascular/Intravascular, Manual Compression): Intra and Extravascular

Implant Material: Resorbable collagen and anchor (sandwich the access site)

Suitable Arteriotomy Size (F): 10-20 device or sheaths (12-25 OD)

Resorption of Implant (days): ~180

Preferred Use: Large bore femoral artery hemostasis

view details

Angio-Seal VIP

Type: Vascular closure device (VCD)

Category (Extravascular/Intravascular, Manual Compression): Intra and Extravascular

Implant Material: Resorbable collagen, anchor, and suture (polyglycolic acid) (sandwich the access site)

Suitable Arteriotomy Size (F): 6, 8

Resorption of Implant (days): 60-90

Preferred Use: Femoral artery hemostasis by manual tightening suture; FDA labeling for immediate restick.

view details

Angio-Seal Evolution

Type: Vascular closure device (VCD)

Category (Extravascular/Intravascular, Manual Compression): Intra and Extravascular

Implant Material: Resorbable collagen, anchor, and suture (sandwich the access site)

Suitable Arteriotomy Size (F): 6, 8

Resorption of Implant (days): 60-90

Preferred Use: Femoral artery hemostasis by using automated collagen compaction and enhanced ease-of-use design; FDA labeling for immediate restick.

view details

StarClose SE

Manufacturer: Abbott

Type: Vascular closure device (VCD)

Category (Extravascular/Intravascular, Manual Compression): Extravascular VCD

Implant Material: Nitinol clip (4mm in diameter and 0.2 mm thickness)

Suitable Arteriotomy Size (F): 5-6

Resorption of Implant (days): NA

Preferred Use: Common Femoral artery hemostasis

view details

Vascade

Manufacturer: Cardiva Medical, Inc.

Type: Vascular closure device (VCD)

Category (Extravascular/Intravascular, Manual Compression): Extravascular VCD

Implant Material: Bioabsorbable Collagen

Suitable Arteriotomy Size (F): 5, 6, 7

Resorption of Implant (days): NA

Preferred Use: Common Femoral artery hemostasis

view details

Vascade MVP

Manufacturer: Cardiva Medical, Inc.

Type: Vascular closure device (VCD)

Category (Extravascular/Intravascular, Manual Compression): Extravascular VCD

Implant Material: Bioabsorbable Collagen

Suitable Arteriotomy Size (F): 6-12

Resorption of Implant (days): ~30

Preferred Use: Femoral venous hemostasis

view details

ExoSeal

Manufacturer: Cordis/Cardinal Health

Type: Vascular closure device (VCD)

Category (Extravascular/Intravascular, Manual Compression): Extravascular VCD

Implant Material: Bioabsorbable PGA plug

Suitable Arteriotomy Size (F): 5, 6, 7

Resorption of Implant (days): 60-90

Preferred Use: Femoral artery hemostasis

view details

MynxGRIP

Manufacturer: Cordis/Cardinal Health

Type: Vascular closure device (VCD)

Category (Extravascular/Intravascular, Manual Compression): Extravascular VCD

Implant Material: Bioabsorbable polyethylene glycol (PEG) sealant

Suitable Arteriotomy Size (F): 5, 6, 7

Resorption of Implant (days): 30

Preferred Use: Femoral artery hemostasis

view details
Load More
Case ExamplesEducational Content

ATHERECTOMY COMPLICATIONS

Case ExamplesEducational Content

BYPASS GRAFT COMPLICATIONS

ModelBurst (ATM)Diameter (mm)Balloon Length (mm)
681215202530
MINI TREK (CTO INDICATED)1.271.2✓✓✓✓✓
1.561.5✓✓✓✓✓
2.172✓✓✓✓✓✓*✓*
TREK2.372.25✓✓✓✓✓✓✓
2.672.5✓✓✓✓✓✓✓
2.912.75✓✓✓✓✓✓✓
3.113✓✓✓✓✓✓✓
3.53.25✓✓✓✓✓✓✓
3.73.5✓✓✓✓✓✓✓
3.943.75✓✓✓✓✓✓✓
4.324✓✓✓✓✓✓✓
4.864.5✓✓
5.365✓✓
*Only available as RX, not as OTW. Other sizes available in both versions.
Retrieved on April 07 2022 from Abbott product ordering information. Please look at the company's files for the latest available data on device configurations and avilability in your area.

Left Main DK Crush Video ID